  series am 3gh -z 3 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12. c 1 of 4 north america only features: ? sip 8 package ? ultra - wide input range 4:1 ? low ripple and noise ? 1 6 00vdc i/o isolation ? continuous short circuit protection ? efficiency up to 82% ? - 40oc to + 85oc operating temperature range ? remote on/off control models single output model i nput voltage (v) output voltage (v) output current max ( ma) maximum capacitive load (f) efficiency (%) am3gh - 1203sz 4.5 - 18 3.3 700 1760 72 am3gh - 1205sz 4.5 - 18 5 600 1000 7 7 am3gh - 1212sz 4.5 - 18 12 250 170 81 am3gh - 1215sz 4.5 - 18 15 200 110 81 am3gh - 24 03sz 9 - 36 3.3 700 1760 7 5 am3gh - 2405sz 9 - 36 5 600 1000 79 am3gh - 2412sz 9 - 36 12 250 170 82 am3gh - 2415sz 9 - 36 15 200 110 82 am3gh - 4803sz 18 - 75 3.3 700 1760 7 am3gh - 4805sz 18 - 75 5 600 1000 7 8 am3gh - 4812sz 18 - 75 12 250 170 8 0 am3gh - 4815sz 18 - 75 15 200 1 10 8 1 models dual output model input voltage (v) output voltage (v) output current max (ma) maximum capacitive load (f) efficiency (%) am3gh - 1205dz 4.5 - 18 5 300 470 7 7 am3gh - 1212dz 4.5 - 18 12 125 100 80 am3gh - 1215dz 4.5 - 18 15 100 47 8 0 am3g h - 2405dz 9 - 36 5 300 470 79 am3gh - 2412dz 9 - 36 12 125 100 79 am3gh - 2415dz 9 - 36 15 100 47 8 0 am3gh - 4805dz 18 - 75 5 300 470 79 am3gh - 4812dz 18 - 75 12 125 100 79 am3gh - 4815dz 18 - 75 15 100 47 79 note: all specifications in this datasheet ar e measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. input specifications parameters nominal typical maximum units voltage range 12 4.5 - 18 vdc 24 9 - 36 48 18 - 75 fi lter capacitor start up time 30 ms absolute maximum rating 12 25 vdc 24 50 48 100 peak input voltage time 100 ms on/off c ontrol on 0 to 0.6vdc (or open) ; off :2.7 to 15.0vdc, off idle current: 2 - 4ma no load input current 40 ma inpu t r eflected c urrent 20 ma p - p
series am 3gh -z 3 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12. c 2 of 4 north america only isolation specifications parameters conditions typical rated units tested i/o voltage 3 sec 1600 vdc resistance >1000 mohm capacitance 200 pf output specifications parameters conditions typical maximum units v oltage accuracy 1 % cross regulation (dual output models) 25% load on one output - 100% load on second load 5 % short circuit protection continuous short circuit restart auto - recovery line voltage regulation 0.2 % load voltage regulation from 0% to 100% load 1 % temperature coefficient 0.02 %/ o c ripple & noise 20mhz bandwidth 30 mv p - p general specifications parameters conditions typical maximum units switching frequency 100 % load 100 khz operating temperature - 40 to 85 o c stora ge temperature - 40 to +125 o c maximum case temperature 100 o c derating above 71 c 5 % / o c cooling free air convection humidity 95 % rh case material non conductive black plastic potting material silicon (ul94v - 0 rated) weight 4.8 g dimensions (l x w x h) 0.86 x 0.36 x 0.44 inches 21.85 x 9.20 x 11.10 mm mtbf >1,700 ,000 hrs (mil - hdbk - 217f, ground benign, t=+25oc) maximum soldering temperature 1.5mm from case for 10 second 260 o c transient r ecovery time 250 u s transient recovery de viation 3 % safety specifications parameters agency approval ce standards en55022 : 2006 + a1:2007, class a en55024 :1998 + a1:2001 + a2:2003 iec61000 - 4 - 2:1995 + a1:1998 + a2:2000, perf. criteria b iec61000 - 4 - 3 :2006 , perf. criteria a iec61000 - 4 - 4 :2004 , perf. criteria b (external 220uf/100v cap required) iec61000 - 4 - 5 :2005 , perf. criteria b (external 220uf/100v cap required) iec61000 - 4 - 6 :2007 , perf. criteria a iec61000 - 4 - 8, perf :1993 + a1:2000, criteria a note: also designed to meet iec 60 950 - 1:2001
series am 3gh -z 3 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12. c 3 of 4 north america only pin out specifications nc: not connected dimensions printed face 21.85 (0.85) 10.60 (0.42) 0.50 (0.02) 2.54 (0.10) 17.78 (0.70) 3.05 (0.12) 9.20 (0.36) 11.10 (0.44) 9.20 (0.36) 3.50 (0.14) 0.25 (0.01) 0.50 (0.02) 0.50 (0.02) derating - 40 - 20 0 20 40 60 80 100 100 80 60 40 20 0 safe operating area output power (%) 85 ambient temperature o c free air convection 71 o c 30 pin single dual 1 - v input - v input 2 + v input + v input 3 on/off control on/off control 5 n.c. n.c. 6 + v output + v output 7 - v output common 8 n.c. - v output
series am 3gh -z 3 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12. c 4 of 4 north america only contro l on/off pin connection example vcc r1 r2 zd1 5.1k ttl signal dc / dc converter on / off control recommended circuits conducted and radiated emissions l c 1 dc / dc converter + v input - v input + v output load - v output e ft/ surge c 2 dc / dc converter + v input - v input + v output load - v output 220 uf / 100 v note: 1. datasheets are updated as needed and as such, specifications are subject to change without notice. once printed or downloaded, datasheets are no longer controlled by aimtec; refer to www.aimtec.com for th e most current product specifications. 2. product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measur ed at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time o f publishing this document. cas numbers and other limited information are considered proprietary and may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuc lear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. warranty is in accordance with aimtec?s standard terms of sale available at www.aimtec.com. vcc (vdc) r1 (k ) r2(k) zd1(v , ma) 4.5 - 18 7.5 0 10, 5 9 - 36 18 2.2 18, 5 18 - 75 33 6.8 36, 5 input voltage (v) c1 (uf/v) l(uh) 12 10/35 2.5 24 2.2/35 10 48 2.2/35 18


▲Up To Search▲   

 
Price & Availability of AM3GH-1212SZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X